CFR /  Title 49  /  Part 213  /  Sec. 213.143 Frog guard rails and guard faces; gage.

The guard check and guard face gages in frogs shall be within the limits prescribed in the following table-- ----------------------------------------------------------------------------------------------------------------

Guard check gage The distance

between the gage line of a frog

to the guard line \1\ of its Guard face gage The distance between

guard rail or guarding face, guard lines \1\, measured across the

Class of track measured across the track at track at right angles to the gage

right angles to the gage line line \2\, may not be more than--

\2\, may not be less than--

----------------------------------------------------------------------------------------------------------------Class 1 track........................... 46\1/8\............. 4 5\1/4\Class 2 track........................... 46\1/4\............. 4 5\1/8\Class 3 and 4 track..................... 4 6\3/8\............ 45\1/8\Class 5 track........................... 46\1/2\............. 4 5----------------------------------------------------------------------------------------------------------------\1\ A line along that side of the flangeway which is nearer to the center of the track and at the same elevation

as the gage line.\2\ A line \5/8\ inch below the top of the center line of the head of the running rail, or corresponding

location of the tread portion of the track structure.

[GRAPHIC] [TIFF OMITTED] TR22JN98.006

[GRAPHIC] [TIFF OMITTED] TR22JN98.007