Within 30 days after you permanently plug a well, you must submit form BSEE-0124, Application for Permit to Modify (subsequent report), to the appropriate District Manager, and include the following information:
(a) Information included in Sec. 250.1712 with a final well schematic;
(b) Description of the plugging work;
(c) Nature and quantities of material used in the plugs; and
(d) If you cut and pulled any casing string, the following information:
(1) A description of the methods used (including information on explosives, if used);
(2) Size and amount of casing removed; and
(3) Casing removal depth.
Temporary Abandoned Wells